Please note:
- Crown and bridge frameworks as a reduced tooth shape with anatomical and ceramic-supporting framework design
- Recommended thickness of the substructure at least 0.4 - 0.5 mm; avoid sharp edges and overlapping
- Bridge connectors should have adequate dimensions in the interdental area
- Attach cooling fin to fully veneered bridge units
- Use only cutters suitable for titanium (low speed, approx. 15,000 rpm and reduced pressure), grind in one direction only and avoid overlapping.
- Sandblast at an angle of 45° using high-grade corundum (120 – 150 µm) at 2 bar and a distance of 3 - 5 cm
- Passivation for five minutes is required (leave framework in place, without machining)
- Cleaning the surface with a steam cleaner
- No oxide firing