Finalization of the final denture bases

  • Consider additional sandblasting of the interdental spaces with Al2O3 (50 μm, 2 – 3 bar) to ensure a good bonding of VITA VM LC flow to the base material and the denture teeth.
  • Moisten the sandblasted areas with VITA VM LC MODELLING LIQUID for the bond between the denture teeth and VITA VM LC flow materials.
  • Then use VITA VM LC flow (5 gingiva shades and/or Window) to close the interdental spaces.
  • Please conduct the surface processing and polishing according to the analogous full denture.
  • Check the occlusion in the articulator. After adjusting the muscle balance, reocclusion by the practitioner is recommended after a wearing time of about two days.
  • When using the light-curing microparticle composite VITA VM LC flow, please observe the processing instructions of this product.
  • The curing parameters may vary depending on the device used. Please observe the manufacturer‘s recommendations (detailed instructions can be found at www.vita-zahnfabrik.com).